Chapter 4 Runtime Operation
4-12 3BUR 001 085R0001 REV A
4.3.5 Smart Device Tuning Overview Display
The Smart Device Tuning Overview Display shown in Figure 4-9 provides information read
from the transmitter data base and the transmitter itself in a split screen format.
Upon entering the display, the left and right portions of the screen contain the same information.
The left portion of the display contains a local copy of the transmitter data base. The right
portion of the display contains smart device configuration information pertaining to the
transmitter data base read from the smart transmitter on a continual basis.
You can change the local information in the left portion of the screen and download these
changes to the transmitter as described in Section 4.3.5.1, Tuning Smart Devices via the
Smart Device Tuning Overview Display.
In the lower left portion of the display is a box containing the SCALING FACTORS used by the
four process variables. These values may be changed and downloaded just as the other data, but
since this data is not stored in the database, the current values cannot be displayed on the right
side. Changes to these values will be reflected in the precision of the process variables.
Figure 4-9. Smart Device Tuning Overview Display
SYSTEM STATUS
DEVICE TUNING
07 JAN 97 09:25:36
FETCH
ALARM
MSG
LAST
PAGE
DEVICE
OVER
DEVICE
I/O
DNLD
CONFIG
PAGE
FORWRD
PAGE
BACK
QUIT
SMART DEVICE TUNING OVERVIEW
PORT ID = SDI_PORT1 PORT STATE = ACTIVE
PORT NO.: 1
DESC: COOLING FLOW PRESS DEVICE STATUS: ACTIVE
PV:
SV:
TV:
4V:
NETWORK: 1 CCF TAG: FTPID-101
MOD300 CONFIGURATION PAGE 1 OF 1
DEVICE TYPE: 3044C TEMP
DEVICE ID: HTFT-101
MESG:
UNITS:
OUTPUT:
RANGE
4 mA
20 mA
DATE:
DESC:
DAMPING:
SENSOR LIMITS
LOW
HIGH
0.0
1.2
-10.0
10.0
CALIBRATED
DEG F
LINEAR
02-NOV-1991
OUTER FLOW
0.0 SEC
0.57 DEG F
12.3 PSI
0.0
0.0
(THIS BUFFER MAY BE EDITED)
SMART DEVICE CONFIGURATION PAGE 1 OF 1
DEVICE TYPE: 3044C TEMP
DEVICE ID: HTFT-101
MESG:
UNITS:
OUTPUT:
RANGE
4mA
20 mA
DESC:
DAMPING:
SENSOR LIMITS
LOW
HIGH
0.0
1.2
-10.0
10.0
CALIBRATED
DEG F
LINEAR
OUTER FLOW
0.0 SEC
CANCEL
DEVICE: 1
DATE: 02-NOV-1991
DEVICE MESGS: DOWNLOAD ERROR - CHECK DIAG DISPLAY
TRANSMITTER ERROR - CHECK DIAG DISPLAY
SCALING
FACTORS
TV:
PV:
4V:
SV: