Black Box AC2000A Especificaciones Pagina 7

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 45
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 6
7
HOW TO USE THE BONUS TABLE
Think of the bonus table as the total amount of EXTRA tokens
after the regular payout, that you wish to receive:
EXAMPLE: PAYOUT: 4 tokens for $1, 24 for a $5, 52 for a $10,
120 for a $20.
24 tokens = $1 extra in tokens
52 tokens = $3 extra in tokens
120 tkns = $10 extra in tokens.
Now go to the bonus table, find where the $5 column =$1
Look over to the $10 and go down until you see $3.
Finally go to the $20 column to where = $10.
You should be at 1-3-7; Turn “ON” your right dipswitches 1-3-7
to set this payout.
DIPSWITCHES
The following table shows how to set the dip switches to your
desired payout.
“ON” COINS PER DOLLAR
#1 1
#2 2
#3 4
#4 8
The left DipSwitch controls the left hopper’s pay out and the
right DipSwitch controls the right hopper’s pay out.
Refer to the next table to set up your changer for the settings you
need.
MODE DESCRIPTIONS
Some of the modes are self-explanatory while others have
sub modes built into the chip. Here is a list of the modes
and sub modes when applicable.
MODE 2 - $1 coins the balance in quarters:
The quarters for each bill are controlled by the sub mode
settings of the right dipswitches #1 & #2.
Neither “ON” – 16 Quarters balance in $1 coins.
#1 “ON” only – 8 Quarters balance in $1 coins.
#2 “ON” only – 12 Quarters balance in $1 coins.
#1 & #2 “ON” – 4 Quarters balance in $1 coins.
MODES’ #5 & #11 – Setting right dips in “$1
increments”:
Refer to Page 6 Under “Dipswitches Cont.”. But instead
of counting up in coins, think of it as dollars.
MODE #14 – Canadian $1 &$2 coin payout:
The right dipswitches #1 & #2 can alter the amount of $1
coins given to each denomination.
Luni’s per $ $5 $10 $20
Neither “ON” - 1L 0L 0L
#1 “ON” 3L 2L 2L
#2 “ON” 3L 4L 4L
The machine will always give 2 Luni’s for a Tuni.
FUSE
High voltage fuse: This is the primary transformer AC fuse
for the main logic board and the validator. Any direct short
of the Transformer or validator will cause this fuse to blow.
Replace this fuse with a 2-½ amp AS fuse only.
REPLACING THIS FUSE WITH ANYTHING OTHER
THAN A 2 ½ AMP “GDC” MAY RESULT IN A FIRE OR
AN UNSAFE WORKING CONDITION!! (See fig. 1 for
location of this fuse.)
Indicator Lights
Main Logic Board:
1. Green LED on: AC power applied to the logic board, all
fuses are good.
2. Decimal Point & Red LED:
A. Heartbeat - 5 and 12vdc present. The changer is in
standby waiting for a bill pulse.
B. On Steady - Out of service, Hopper error detected.
Validator logic board:
1. Red LED
A. On Steady - Standby Mode, waiting for bill
insertion.
B. Flashing - Error mode, go to page for error code
information.
C. Off - The changer “Empty” LED is lit.
WIRE HARNESS COLOR AND DEFINITIONS
Validator harness:
Red - Switched Hot 120VAC
White - Neutral 120VAC
Black - 120VAC Low current validator enable
Yellow - +5vdc credit pulse line
Blue - -5vdc credit pulse line
Orange - +12vdc Empty LED
Brown - -12vdc Empty LED
Hopper Harness
Gray - Coin counting optic status line
White - Low coin sense (+5vdc)
Green - Coin counting optic pay out feedback line
Yellow - Raw sensor output line
Purple - Hopper pay out line from main logic board (+)
Brown - Hopper pay out line from main logic board (-)
Red - +12vdc logic board supply voltage
Black(s) -12v, 24v low coin sense ground
Orange - +24vdc Motor supply voltage
Vista de pagina 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 44 45

Comentarios a estos manuales

Sin comentarios