SERVSWITCH™ AFFINITY
To use a kit to mount a ServSwitch Affinity, take these steps, referring to
Figure G-1:
1. Unscrew and remove the two screws on each side of the Affinity.
2. Match up the two holes in the “chassis end” of each kit ear with the two holes
that you just removed the screws from, then fasten the ear to the Affinity with
two of the new screws included with the kit.
3. Once you’ve attached both ears, match the holes in the “rack end” of each ear
to an appropriate set of matching holes on your equipment rack, then screw
the Affinity assembly to the rack using your own screws, bolts, or cage nuts
(not included).
Figure G-1. Rackmount assembly.