CHAPTER 12: Testing and Troubleshooting
remote unit is error free. Run the test using all available test patterns.
NOTE
If an external BERT tester is available, these additional tests may be
performed:
DTE & Loop Test
DTE Only Test
Loop Only Test
If the unit fails any of these tests or the problem has not been determined, contact
Black Box.
12.3 Local Unit Diagnostics
The local CSU/DSU MS DBU can perform six different tests; see Table 12-3.
Table 12-3. Test AT Commands
Front-Panel Display AT Command Description
DTE & Loop (LL) &T10 TD/RD and RX/TX Loopbacks
Loop Only (RT) &T11 RX/TX Loopback at Network Interface
DTE Only &T1 TX/RX Loopback at DTE Interface
DTE with TP &T8 TX/RX Loopback with Test Pattern
Test Pattern &T9 Transmit/Receive Test Pattern
Self Test Z Check Internal Components (Resets Unit)
Exit Test &T0 Stops test, returns to data mode
TD = Customer Transmit Data
RD = Customer Receive Data
TX = Network Transmit Data
RX = Network Receive Data
The test patterns shown in Table 12-4 are available for the DTE with Test Pattern
and Test Pattern tests.