Black Box AC1037A-XMIT Manual de usuario

Busca en linea o descarga Manual de usuario para Controles remotos Black Box AC1037A-XMIT. COM-120B Evaluation Guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - Rev. 1.0 Page 1

Rev. 1.0 Page 1http://www.avionteq.com/IFR-Aeroflex-COM-120B-Communications-Service-Monitor.aspxwww.avionteq.com

Pagina 2 - Rev. 1.0 Page 2

Rev. 1.0 Page 10 Basic Operation and NavigationThis guide will provide some basic operational knowledge to allowconfiguration of the COM-120B but you

Pagina 3 - Rev. 1.0 Page 3

Rev. 1.0 Page 11With the cursor still on the INPUT field, notice that the F1 and F2 keylabels offer quick entry of the available selections. Quick en

Pagina 4 - Rev. 1.0 Page 4

Rev. 1.0 Page 12Meter functions allow for zooming aswell. In the example to the right, thecursor is placed on the RF Power meterfield label. This al

Pagina 5 - Continuos

Rev. 1.0 Page 13SHOWListSTARTSTOPSetting up the Demonstration SoftwareTo access the System Setup Software used in this document, a programmust be acti

Pagina 6 - Rev. 1.0 Page 6

Rev. 1.0 Page 14REC – Transmitter Test ScreenExploded view of the function screens that are available in the RECscreen.

Pagina 7 - Master Power

Rev. 1.0 Page 15Interconnect:1. Connect the supplied Transmitter RF Output to the COM-120B’s T/RInput.2. Turn the radio to the ON position and set t

Pagina 8 - Rev. 1.0 Page 8

Rev. 1.0 Page 16STARTSTOPFind Transmit FrequencySetup:1. This COM-120B has been pre-configured for common transmitter testsetups.2. Press the key to

Pagina 9 - Rev. 1.0 Page 9

Rev. 1.0 Page 17TX Frequency TuningEither the Scope or Spectrum Analyzer canbe viewed by positioning the cursor to theSCOPE or ANALYZER field and sele

Pagina 10 - Function Keys F1 – F6

Rev. 1.0 Page 18Signal Find FeatureThe Signal find feature is a function of the Spectrum Analyzer. To viewthe Spectrum Analyzer press the ANLYZ key o

Pagina 11 - Rev. 1.0 Page 11

Rev. 1.0 Page 19STARTSTOPTest Voice DeviationSetup:1. This COM-120B has been pre-configured for common transmitter testsetups.2. Press the key to ac

Pagina 13 - Rev. 1.0 Page 13

Rev. 1.0 Page 208. Position the cursor to the ScopeLabel by pressing [TAB] [1] [ENTER]on the COM-120B’s keypad.9. Press the F1 key labeled “ZOOM” toe

Pagina 14 - REC – Transmitter Test Screen

Rev. 1.0 Page 21STARTSTOPThe AF Countermeasures theCTCSS code to 1 Hzresolution. Forgreater resolution,this meter can beexpanded.The Modulation meter

Pagina 15 - Rev. 1.0 Page 15

Rev. 1.0 Page 22STARTSTOPThe Modulation meterand Data Decoderhave been configuredfor a 300 Hz Low Passfilter for this test.Test TX Squelch (DCS)Setup:

Pagina 16 - Find Transmit Frequency

Rev. 1.0 Page 23STARTSTOPTest TX DTMF DecodeSetup:1. This COM-120B has been pre-configured for common transmitter testsetups.2. Press the key to acc

Pagina 17 - TX Frequency Tuning

Rev. 1.0 Page 243. The supplied transmitter does not have a DTMF keypad so the COM-120B’s internal DTMF generator will be used to simulate pressingke

Pagina 18 - RF spectrum can be searched

Rev. 1.0 Page 25STARTSTOPTest TX DistortionSetup:1. This COM-120B has been pre-configured for common transmitter testsetups.2. Press the key to acce

Pagina 19 - Test Voice Deviation

Rev. 1.0 Page 26Measuring TX Distortion:1. With the radio configured to channel 2, key the radio and observe a 1kHz tone on the Scope at a level of 3

Pagina 20 - The Modulation meter

Rev. 1.0 Page 27This concludes the Transmitter test section of this procedure. If youwould like ot try it out with one of your own radios, you may do

Pagina 21 - Test TX Squelch (CTCSS)

Rev. 1.0 Page 28GEN – Receiver Test ScreenExploded view of the function screens that are available in the GENscreen.The generate screen provides all o

Pagina 22 - Test TX Squelch (DCS)

Rev. 1.0 Page 29GEN – Receiver Test ScreenModulation SourcesThe COM-120B can be simultaneously modulated by up to 6modulation sources. AM and FM can

Pagina 23 - Test TX DTMF Decode

Rev. 1.0 Page 3Thank you for taking the time to evaluate the IFR COM-120B. We knowthat your time is valuable, so we have included a demonstration kit

Pagina 24 - Rev. 1.0 Page 24

Rev. 1.0 Page 30STARTSTOPSetup:1. This COM-120B has been pre-configured for common receiver testsetups.2. Press the key to accessthe COM-120B System

Pagina 25 - Test TX Distortion

Rev. 1.0 Page 31SINAD =Signal + Noise + DistortionNoise + DistortionThe COM-120B has beenconfigured with theAUDIO/DATA Input routedto the scope to vie

Pagina 26 - Rev. 1.0 Page 26

Rev. 1.0 Page 32The SINAD meter can be expanded to allow more control by positioningthe cursor to the SINAD meter label [TAB] [1] [6] [ENTER] and pres

Pagina 27 - Rev. 1.0 Page 27

Rev. 1.0 Page 33DUPLEX Operation ModeDuplexModeSimultaneous Generate and Receive operation for Full DuplexAny Offset between Generate and Receive freq

Pagina 28 - GEN – Receiver Test Screen

Rev. 1.0 Page 34The Duplex screen offers the ability to generate and receive at the sametime. Additionally, the Generate and Receive frequencies may

Pagina 29 - Modulation Sources

Rev. 1.0 Page 35This concludes the Receiver test procedure. There are other tests thatcan be performed on the receiver but are beyond the scope of th

Pagina 30 - Rev. 1.0 Page 30

Rev. 1.0 Page 36STARTSTOPMeasuring FiltersInterconnect:1. Connect an RF cable to the COM-120B’s AUX RF Output.2. Connect an RF cable to the COM-120B

Pagina 31 - Rev. 1.0 Page 31

Rev. 1.0 Page 37The Tracking Generator function allows analysis of:! Filter Insertion Loss! Filter Notch Depth! Filter Pass band! Filter BandwidthT

Pagina 32 - Rev. 1.0 Page 32

Rev. 1.0 Page 381. Connect the Duplexer Antenna port to the COM-120B’s AUX RFOutput.2. Connect the Duplexer 160 MHz port to the COM-120B’s Antennapo

Pagina 33 - DUPLEX Operation Mode

Rev. 1.0 Page 39Position the cursor to the Atten fieldand select 0 dB input attenuation bypressing the F2 key. The right sidemay now be evaluated for

Pagina 34 - Rev. 1.0 Page 34

Rev. 1.0 Page 4! RF Inputs and Outputs! Audio Inputs and Outputs! Rear Panel! Basic Operation / Navigation! Using the SETUP software! Transmitte

Pagina 35 - Rev. 1.0 Page 35

Rev. 1.0 Page 40STARTSTOPMeasuring Cable FaultSetup:1. This COM-120B has been pre-configured for common Analyzer testsetups.2. Press the key to acce

Pagina 36 - Measuring Filters

Rev. 1.0 Page 411. Position the cursor to the Markerfield label.2. Press the F1 key to activate marker.3. Press the ENTER key to edit theMarker Fre

Pagina 37 - Rev. 1.0 Page 37

Rev. 1.0 Page 42STARTSTOPMeasuring Return LossInterconnect:1. Connect the Return Loss Bridge as indicated in the graphic above.2. Connect the Bridge

Pagina 38

Rev. 1.0 Page 433. The menu to the right will appear.4. Select STEP 10 by positioning thecursor and pressing F1 Execute.5. The COM-120B will config

Pagina 39 - Rev. 1.0 Page 39

Rev. 1.0 Page 44This concludes the COM-120B Evaluation procedure. If you would likeinformation or assistance with tests not covered by this procedure

Pagina 40 - Measuring Cable Fault

Rev. 1.0 Page 45! RF Signal Generator! Output Level +13 to -130! 0.2 PPM TCXO! 2 uV Receiver with 15, 30 and 300 kHz IF filters! 50 kHz Scope! F

Pagina 41 - Rev. 1.0 Page 41

Rev. 1.0 Page 46! 0.01 PPM OCXO (120B-xTx)! Internal Rechargeable Battery (AC3001)! Tracking Generator (AC3012)! Return Loss Bridge (AC4105)! Eas

Pagina 42 - Measuring Return Loss

Rev. 1.0 Page 5Off the AirTransmitterconnectionFull DuplexTestingReceiverHalf-Duplextesting+13 dBmTrackingGeneratorOutputTransmitterInputUp to 50Watts

Pagina 43 - Return Loss

Rev. 1.0 Page 6External Modsource for radiounder testScope / DVM Input(200 VRMS Max)AUDIO / DATASINAD IN(15mV – 15V)EXT MOD IN2 kHz / Vpk Narrow10 kHz

Pagina 44 - Rev. 1.0 Page 44

Rev. 1.0 Page 7RS-232 Serial I/ODirect pin to pin connection to PC10 MHz Ext.Reference InputOptionalGPIBInterfaceBatteryCompartmentReplaceableBattery

Pagina 45 - Rev. 1.0 Page 45

Rev. 1.0 Page 8For the purpose of demonstration, this demo unit has been configuredwith software to perform specific setups that coincide with thisdoc

Pagina 46 - Rev. 1.0 Page 46

Rev. 1.0 Page 91. Remove the connector kit from the Evaluation Kit and Connect the N-BNC adapter to the COM-120B’s T/R RF IN/OUT connector locatedin

Comentarios a estos manuales

Sin comentarios