Page 22 of 98 The Black Box Toolkit
Copyright © 2004 The Black Box Toolkit Ltd. All rights reserved.
free to activate either button of the mouse in response to events on the remote PC. These
leads plug into the toolkit using the 2.5mm sockets (lines 7 and 8). The green LEDs
indicate switch closure activity.
If you wish to make use of the two additional active switch closure lines (lines 5 and 6) you
will need to purchase additional leads for this purpose as they use different size jack plugs.
These are available at reasonable cost from our distributors. If you are using both the
powered-out lines for active switch closure you will not be able to use them to power the
toolkit tone generators. Please see section 13.3.1. for details on how to connect these
lines to suitable equipment buttons etc.
Typically you can use the active switch closure lines to activate any switched device, e.g.
mouse button, key on a keyboard, button on a response pad etc. You can also use the
powered digital optically isolated lines 5 and 6 to generate pulse trains if required.
Note: If you decide to make use of the active switch closure feature, you do so
entirely at your own risk. It is assumed that your local technical staff will be on-hand
to advise as needed. We cannot be held responsible for any damage caused to
your own equipment through incorrect wiring. In addition any damage caused to
the toolkit as a result will void your warranty.