Vista de pagina 0
CUSTOMER
SUPPORT
INFORMATION
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)
FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746
Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018
Web site: www.blackbox.com • E-mail: [email protected]
AUGUST 1999
MD885A-R2
MD885A-R3
MD885AE-R2
MD885C-R2
Modem 34336
MODEM
34336
1
2
3
ENT
1
2
3
601745301 Rev. A
NOTE
All models include the modem, (1) leased line cable, (1) dialup phone cable
and this user manual. The MD885A-R2, MD885AE-R2, and MD885A-R3
include a power supply. The MD885A-R3 also includes (1) 10-ft. RS-232
cable and (1) DB9 F to DB25 M adapter.
Vista de pagina 0
1 2 3 4 5 6 ... 149 150

Indice de contenidos

Pagina 1 - Modem 34336

CUSTOMERSUPPORTINFORMATIONOrder toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)FREE technical support 24 hours a day, 7 days

Pagina 2 - INDUSTRY CANADA

92.0 Quick Start • If you are operating the Modem in a manual dial mode, you also needa standard telephone set.2.1.4 CONNECTIONSFigure 2-1 shows how

Pagina 3 - Table of Contents

995.0 Hayes Emulation ModeTable 5-1 (continued). Hayes Compatible Commands.COMMAND FUNCTION/EXPLANATIONY Long-Space Disconnect*Y0 Disables long-spac

Pagina 4

100Modem 34336Table 5-1 (continued). Hayes Compatible Commands.COMMAND FUNCTION/EXPLANATION&J Modem displays OK result code; command has no othe

Pagina 5

1015.0 Hayes Emulation ModeTable 5-1 (continued). Hayes Compatible Commands.COMMAND FUNCTION/EXPLANATION&T Test Commands &T0 Terminates a

Pagina 6 - Table of Conents

102Modem 34336Table 5-1 (continued). Hayes Compatible Commands.COMMAND FUNCTION/EXPLANATION&Z Store Telephone NumberParameters are 0-9 (availab

Pagina 7 - 1.0 Specifications

1035.0 Hayes Emulation ModeTable 5-1(continued). Hayes Compatible Commands.COMMAND FUNCTION/EXPLANATION\N V.42 Mode * 1 \N0 Disables error correct

Pagina 8 - 1.0 Specifications

104Modem 34336Table 5-2. Hayes Mode Result Codes.DIGIT CODE WORD CODE MEANING0 OK Command line executed without errors. 1 CONNECT Carrier de

Pagina 9 - 2.0 Quick Start

1055.0 Hayes Emulation ModeTable 5-2 (continued). Hayes Mode Result Codes.DIGIT CODE WORD CODE MEANING15 CONNECT 4800 Carrier detected at 4800 b

Pagina 10 - 2.0 Quick Start

106Modem 34336Table 5-3. S Register Functions.(Only registers intended for user access are listed.)REGISTER RANGE UNITS DEFAULT DESCRIPTIONS0 0-255

Pagina 11

1076.0 V.25 bis Autodialer6.0 V.25 bis AutodialerFor international compatibility, the Modem can function as a V.25 bisautodialer. In V.25 bis mode,

Pagina 12

108Modem 34336DTR DIALING INV.25 BISMODEAn alternative to using the V.25bis CRS command to dial a stored number isto use the DTR dialing option. With

Pagina 13

10Modem 34336For dialup applications:• Use the supplied two-conductor crossover cable to connect the Modemto the telephone-line modular wall jack. Pl

Pagina 14 - 2.3 Quick Setup

1096.0 V.25 bis Autodialer• DIC — Disregard Incoming Call. The DIC command instructs theautodialer not to answer an incoming call. The DIC command i

Pagina 15

Table 6-1. V.25 bis Autodialer Commands.COMMAND FUNCTIONCIC Connect incoming call. CRN n Call request—dial number (n) entered on DTE keyboard.

Pagina 16

1116.0 V.25 bis AutodialerTable 6-2. V.25 bis Dialing Parameters.(Table also applies to Dumb mode and Bell 208 operation)Characters that can be dial

Pagina 17 - 2.4 Basic Operation

6.3 Dialing ParametersTable 6-2 lists dialing parameters you can use with the CRN commandto modify dialing operations.6.4 V.25 bis Result CodesTable 6

Pagina 18

1137.0 Diagnostics7.0 DiagnosticsThe troubleshooting information in this chapter applies to all Modemapplications (all dialup and leased line modes),

Pagina 19

114Modem 343367.3 Physical InspectionThe next step in isolating a defective component is inspecting the system.If you can trace the problem to a speci

Pagina 20

1157.0 Diagnostics7.5 How to Select and Activate Tests7.5.1 FRONT-PANELCONTROLTests are accessed and activated in the same way options are selected:

Pagina 21

116Modem 34336D = Dial line occupiedR = Ringing (R appears in same position as D.)S = Connection secured by security handshake (S appears in same posi

Pagina 22

1177.0 DiagnosticsThe RX value is the local receive level of the incoming signal. The receivelevel range of measurement is from 0 to -43 dBm in 1.5-

Pagina 23

118Modem 343367.7 Local Modem Diagnostics Local modem diagnostics are for testing the Modem and its adjoining system.The tests are accessed from the

Pagina 24

112.0 Quick Start 2.2 Front-Panel LCD and ControlsTo select a Quick Setup configuration, you will need to use the pushbuttonsand liquid-crystal displ

Pagina 25

1197.0 DiagnosticsIn Hayes emulation mode only, initiate the ALB test using the command &T1(preceded by AT). In any mode, initiate the ALB test u

Pagina 26 - 2.5 Problem Solving

120Modem 34336Figure 7-2. Analog Loopback Self-Test (ALBST).The SELFTEST screen is displayed, with ON and OFF as the possibleselections. Select ON to

Pagina 27

1217.0 DiagnosticsTo run the test, go to the LCD MAIN MENU. From page 2 of the LCD MAINMENU, select TEST. This takes you to screen 1 of the LOCAL TES

Pagina 28 - 3.0 Modem Setup Options

122Modem 34336NOTEThe ALBX test may result in errors or may fail altogether even whereconditions are satisfactory for normal operation. The test chan

Pagina 29

1237.0 Diagnostics7.7.5 EXTERNALANALOGLOOPBACKSELF-TEST(ALXST)The external analog loopback self-test is available for 4-wire leased line modeonly.Th

Pagina 30 - 3.0 Modem Setup Options

124Modem 34336To initiate the ALXST, use the Modem’s front-panel controls to go to theLCD MAIN MENU. From page 2 of the LCD MAIN MENU, select TEST. G

Pagina 31

1257.0 DiagnosticsFigure 7-5. Digital Loopback Test (DLB).The DIGITAL LOOPBACK screen is displayed, with ON and OFF as thepossible selections. Selec

Pagina 32 - 3.3 Options

126Modem 343367.8 Remote Modem DiagnosticsThe Modem performs two tests on compatible remote modems: remotedigital loopback (RDL) and remote digital lo

Pagina 33

1277.0 DiagnosticsFrom page 2 of the MAIN MENU, select RMT. Then select TEST. From the REMOTE TEST menu, select RDL.From the REMOTE DIGIT LOOP scree

Pagina 34

128Modem 34336Figure 7-7. Remote Digital Loopback Self Test.PATTERNGENERATORPATTERNDETECTORTRANSMITTERRECEIVERTRANSMITTERRECEIVERLOCAL MODEMREMOTE MO

Pagina 35

12Modem 343362.2.2 EIA STATUSSCREENThe EIA status screen indicates the operational status of the Modem as wellas the condition of certain EIA RS-232

Pagina 36

129APPENDIX A: DB25 Pin AssignmentsAppendix A: DB25 Pin AssignmentsDesig- LCDPin nation Function Indicator Source1 AA Frame ground—not connected2 BA

Pagina 37

130Modem 34336Appendix B: Quick Setup ConfigurationsTable B-1 shows the complete default configuration for each of the QuickSetup modes. When you sele

Pagina 38

131APPENDIX B: Quick Setup ConfigurationsTable B-1 (continued). Quick Setup Configurations.Default Settings Listed by Mode or Type of OperationV.25 b

Pagina 39

132Modem 34336Table B-1 (continued). Quick Setup Configurations.Default Settings Listed by Mode or Type of OperationV.25 bis 2-WIRE 4-WIRE BELLOPTION

Pagina 40

133APPENDIX B: Quick Setup ConfigurationsTable B-1 (continued). Quick Setup Configurations.Default Settings Listed by Mode or Type of OperationV.25 b

Pagina 41

134Modem 34336Table B-1 (continued). Quick Setup Configurations.Notes:1V.25 bis synchronous configurations (character- and bit-oriented) are the same

Pagina 42

135APPENDIX C: Summary SetupAppendix C: Summary SetupC.1 Introduction to Summary SetupSummary Setup is designed to allow experienced users to quickl

Pagina 43

The AT PROFILES screenallows you to access andchange the Hayes mode userprofiles (profile 0 and profile 1).136Modem 34336The SETUPS screenallows you t

Pagina 44

137Appendix C: Summary SetupC.2 SETUPS ScreenOnly part of the SETUPS screen can bedisplayed at any one time. The full screenis displayed below next

Pagina 45

138Modem 34336Primary Options:addr999 999Group Unitaddress addressFigure C-2. How to move the cursor in the SETUPS screen using the pushbuttons.Dial

Pagina 46

132.0 Quick Start 2.3 Quick SetupTo set up the Modem for immediate use (or to quickly change the modem’sconfiguration for an alternate mode of operat

Pagina 47

139Appendix C: Summary SetupV.42 ERROR CORRECTION OPTION:NOTE“V42 <1>” and “V42 <2>” are displayed to help indicate the relativepositions

Pagina 48

140Modem 34336DATA PUMP OPTIONS:NOTE“pump1” and “pump2” are displayed to help indicate the relativepositions of individual options across the LCD.pump

Pagina 49

141Appendix C: Summary SetupMISCELLANEOUS OPTIONS:NOTE“misc1” and “misc2” are displayed to help indicate the relative positionsof individual options

Pagina 50

142Modem 34336C.3 AT PROFILES ScreenFrom the AT PROFILES screen you can select a Hayes mode configurationprofile (either 0 or 1). Only part of the pr

Pagina 51

143Appendix C: Summary SetupC.4 S-REG ScreenThe S-REG screen may be used to read or change the value stored in an Sregister. For more information, s

Pagina 52

144Modem 34336Appendix D: JumpersWARNINGJumpers should be switched only by qualified service personel.For most applications, there is no need to reset

Pagina 53

145Appendix D: JumpersFigure D-1. Modem Circuit Board—Jumper Locations.JP7JP2JP3JP1JP6JP5JP4JP8

Pagina 54

146Modem 34336Table D-1. Jumper Switch Functions.JUMPER(S) Pins 1 and 2 connected Pins 2 and 3 connectedJP1 Frame and signal Frame and signal ground

Pagina 55 - Special Features

147NOM StatementNORMAS OFICIALES MEXICANAS (NOM)ELECTRICAL SAFETY STATEMENTINSTRUCCIONES DE SEGURIDAD1. Todas las instrucciones de seguridad y operaci

Pagina 56

148Modem 3433610. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calorcomo radiadores, registros de calor, estufas u otros apar

Pagina 57

14Modem 34336All options for each Quick Setup configuration are listed in Appendix B.If you want to customize your Quick Setup configuration, see 3.0,

Pagina 58

1000 Park Drive • Lawrence, PA 15055-1018 • 724-746-5500 • Fax 724-746-0746© Copyright 1999. Black Box Corporation. All right

Pagina 59 - 4.4 Dial Line Auto-Recovery

152.0 Quick Start Table 2-1 (continued). Available Quick Setup Configurations.QUICK SETUP <07> 2-WIRE LEASED-LINE ANSWER MODE—2-W LEASED (ANS

Pagina 60 - 4.5 DTR Dialing

16Modem 343362.4 Basic OperationThis section provides basic information for each of the modem’s primaryoperating modes. If you encounter difficulty, r

Pagina 61

172.0 Quick Start Dialing Mode. The default dialing mode is tone dialing. To change to pulsedialing, insert a P after AT D: AT DPTo change from puls

Pagina 62

18Modem 34336For V.25 bis operation, the Modem must be configured to use the same dataprotocol as the attached DTE. V.25 bis mode operation and comman

Pagina 63 - 4.7 Modem Security Operation

1FCC InformationFEDERAL COMMUNICATIONS COMMISSIONANDINDUSTRY CANADARADIO FREQUENCY INTERFERENCE STATEMENTSThis equipment generates, uses, and can radi

Pagina 64 - Table 4-2. Password Commands

192.0 Quick Start 2.4.3 2-WIREDIAL(DUMB) MODE(QUICKSETUP5)Dumb mode is used primarily for manual call origination, answer-onlyapplications, and in c

Pagina 65

20Modem 34336Autodialing the Stored Number. To autodial the stored number fromthe EIA status screen, press the following pushbuttons in sequence:ENT P

Pagina 66

212.0 Quick Start The following information applies to both 2-wire and 4-wire leased-lineoperation:• The modem must be configured for the correct lin

Pagina 67

22Modem 343362.4.5 V.33 LEASED-LINEOPERATION(QUICKSETUP10)V.33 operation is available on the Modem at speeds of 12,000 and 14,400 bps.V.33 leased-line

Pagina 68 - ONTROLLER

232.0 Quick Start 2.4.7 4-WIRELEASEDLINEV.29 MODE(QUICKSETUP13)The 4-Wire Leased Line V.29 Mode configures the modem for V.29operation, for compatibi

Pagina 69

24Modem 343362.4.8 V.29 FASTMASTER ANDSLAVEMODES(QUICKSETUPS14 AND15)In multidrop operation, the master modem transmits to all of the slave(remote) mo

Pagina 70

252.0 Quick Start 2.5 Problem SolvingIf you encounter difficulties in setting up or using the modem, try theremedies described below. If you suspect

Pagina 71

26Modem 34336NOTEThis page is intentionally left blank.

Pagina 72 - 9600 bps or higher

273.0 Modem Setup Options3.0 Modem Setup Options3.1 Methods For Selecting OptionsThe Modem allows you to easily select options for tailoring the mode

Pagina 73

28Modem 343363.2 Selecting Options from the Front-Panel3.2.1 PUSHBUTTONS AND THELCDOptions are selected from the front panel by pressing the front pa

Pagina 74 - IAGNOSTIC

2Modem 34336Table of Contents1.0 Specifications ...62.0 Quick Start.

Pagina 75

293.0 Modem Setup OptionsNOTEIf you have selected a Quick Setup or have changed certain optionssettings, pressing the ENT pushbutton to exit the SETU

Pagina 76 - ISCONNECTING

30Modem 343362. Option-Selection Example. The following example illustrates optionselection. As you follow the steps below, refer to the LCD flow ch

Pagina 77 - 4.10 Automatic Fallback

313.0 Modem Setup OptionsPress pushbutton 3 to select SPKVOL(speaker volume). The SPEAKERVOLUME screen is shown right.The currently selected setting

Pagina 78

32Modem 34336The default settings for each option are listed in Appendix B.The Quick Setup options (one for each operating mode) affect the entiremode

Pagina 79

333.0 Modem Setup OptionsTable 3-1. Effect of Speed Limit Settings on Data RateMAX RATE DIALER SETTING, bps OPTION RESULTANT DATA RATE, bps L

Pagina 80

34Modem 34336• V.32. The Modem normally uses the V.32 handshake. (The Modem alsouses this handshake for V.32/14,400 bps operation.)• V.33. V.33 oper

Pagina 81 - 4.11 V.13 Operation

353.0 Modem Setup Options3.3.1 V.42 ERRORCORRECTIONOPTIONSThe Modem supports both CCITT V.42 error correction and MicrocomNetworking Protocol®(MNP®)

Pagina 82 - 5.0 Hayes Emulation Mode

36Modem 34336The available error correction options are listed below:• V.42 Mode • DTE Speed • MNP Class (class limit) • DTE-DCE and DCE-DTE Flow• Bre

Pagina 83

373.0 Modem Setup OptionsThe following two options are available through the V42 SELECTION screen: The Protocol option is available for Hayes, V.25 b

Pagina 84

38Modem 34336The Buffer Mode/Speed Conversion option Hayes, V.25 bis, Dumb, Leasedline modes (except V.33). It enables or disables speed conversion (f

Pagina 85 - 5.2 Hayes Compatible Commands

3Table of Contents3.3.1 V.42 Error Correction Options ...353.3.2 Dialer Mode ...

Pagina 86

393.0 Modem Setup OptionsThe DTE-DCE Flow Control options are available for Hayes, V.25 bis, Dumb,and Leased-Line modes (except V.33).• NONE — No flo

Pagina 87

40Modem 34336The Pass-Through Flow Control options are available for Hayes, V.25 bis, Dumb,and Leased-Line modes (except V.33). Pass-Through Flow Cont

Pagina 88

413.0 Modem Setup OptionsThe V.25 bis Dialer Modes are available for V.25 bis mode.Any of the selections from the DIAL V25bis screen will enable the

Pagina 89

42Modem 34336The Character Length option is available for all modes (asynchronousoperation only). It selects a character length of 8, 9, 10, or 11 bit

Pagina 90

433.0 Modem Setup Options3.3.4 DISCONNECTOPTIONSWhen the modem is operating in V.25 bis or Dumb mode, it is necessary todisconnect the modem from the

Pagina 91 - 5.3 S Registers

44Modem 343363.3.5 TESTOPTIONSThe Test Options affect certain tests (as explained below) but do not activatetests.The DSR During Analog Loopback is av

Pagina 92

453.0 Modem Setup OptionsNOTEThe Modem also supports a CTS option intended only for V.33and Bell 208A/B operation, described later in this chapter.T

Pagina 93

46Modem 34336The Test Mode (TM to EIA) option is available for all modes. It controlspin 25, the test mode (TM) indicator, on the RS-232 interface con

Pagina 94

473.0 Modem Setup OptionsThe Compromise Equalizers option is available for all modes.NOTEThe compromise equalizers affect only V.32 operation (4800 t

Pagina 95

48Modem 34336Normally, as part of the V.32 handshake, the calling modem begins sendinga sequence to the answer modem while the answer modem is still s

Pagina 96

4Modem 343364.10 Automatic Fallback ...764.10.1 Operating Mode Fallback ...

Pagina 97

493.0 Modem Setup OptionsThe Speaker Volume option is available for all modes. It can be set to LOW,MEDIUM, or HIGH.The Guard Tones option is availab

Pagina 98

50Modem 34336The CTS option is available for 4-wire Leased Line modes. It applies only to 4-wire leased line applications using constant carrier.• RT

Pagina 99

513.0 Modem Setup OptionsThe Turnaround Delay option is available for 208 mode. It is intended forcircuits where echo is a problem. It prevents the

Pagina 100 - 5.0 Hayes Emulation Mode

52Modem 34336• Enable — The Modem will check for X-ON/X-OFF (DC1/DC3)flow control characters received from the remote modem to determinewhether to sto

Pagina 101

533.0 Modem Setup OptionsThe 208 Phase Detection option is for 208 mode. • Normal — Conditions the modem’s 208 receiver for normal modulationdetecti

Pagina 102

54Modem 343364.0 General Operation and Special FeaturesThis chapter describes the following Modem features and operationalmodes (listed here in the or

Pagina 103

554.0 General Operation and Special FeaturesIf a number has been previously stored, the number is displayed on the topline of the LCD (instead of das

Pagina 104

56Modem 34336Table 4-1. Dialing Control Characters.Character FunctionA-D Used in some PBX applications (tone dialing only). L Links a phone number t

Pagina 105

574.0 General Operation and Special Features4.3.1 AUTODIALBACKUPThe Modem automatically dials the stored number to connect over the backupline if it

Pagina 106

58Modem 34336NOTEIf DIAL IF BAD >> (1, 2, 3 or 4) min is selected, the Select option settingof the answer unit must be equal to or less than the

Pagina 107

5Table of Conents7.6 Diagnostic Monitoring: Status Screens ...1157.6.1 EIA Status Screen ...

Pagina 108 - 6.0 V.25 bis Autodialer

594.0 General Operation and Special FeaturesRecovery from the front panel, enter the phone number to be dialed followedby /R (the Dial Line Auto-Reco

Pagina 109

60Modem 343364.5.1 DIALING ASTOREDNUMBERDTR dialing allows you to set up the Modem to automatically dial a storednumber even when the autodialer is no

Pagina 110

614.0 General Operation and Special Featuresplace the handset back on the cradle. The LCD displays the status of thecommunication. It appears as show

Pagina 111

62Modem 343364.7 Modem Security OperationIn 2-Wire-Dial Hayes emulation mode only, the Modem can be configured toprovide security on incoming calls. R

Pagina 112

634.0 General Operation and Special FeaturesThe modem’s security configuration for password protection is controlledfrom the DTE by a special set of

Pagina 113 - 6.4 V.25 bis Result Codes

64Modem 34336Rules for using passwords and password commands are listed below.• Memory locations 0 and 2-9 may be used for storing phone numbers;locat

Pagina 114 - 7.0 Diagnostics

654.0 General Operation and Special Features2.Unlocking the &V and &Z commands. If an administrative password isimplemented, the Hayes compat

Pagina 115 - 7.3 Physical Inspection

66Modem 34336NOTEPasswords may be stored only in memory locations 2 through 9.5.Programming a response to a correct password. Enter the followingcomm

Pagina 116 - 7.0 Diagnostics

674.0 General Operation and Special FeaturesControl Procedure (Modem-to-Modem)Enabling Modem-to-Modem Remote Control ModeTo remotely control a modem

Pagina 117

68Modem 34336Remote control through a rack controller is an especially valuable capabilityfor modem used in high-density 16-slot enclosures. The low-p

Pagina 118

6Modem 343361.0 SpecificationsAvailable Configurations — Stand-alone or rack-mountCompatibility — V.29 9600, 7200, 4800V.32 terbo 19.2 or 16.8 kbpsV.

Pagina 119 - 7.7 Local Modem Diagnostics

694.0 General Operation and Special Features2. Enter the address or slot number—To enter the address or slot numberof the modem to be controlled, pre

Pagina 120

70Modem 34336Figure 4-1. Remote control—address control mode.Modems in rack equppedwith rack controllerStandalone modemsModems in rack with orwithout

Pagina 121

714.0 General Operation and Special Features4.9 Diagnostic Interface ControlThe diagnostic software built into the Modem supports a special set ofcom

Pagina 122

72Modem 34336Table 4-3. Diagnostic Port Commands.COMMAND FUNCTIONCONNECT g,u Connect to diagnostic port of modem at group address g, unit address u.

Pagina 123

734.0 General Operation and Special FeaturesA carriage return [CR] is required at the end of a command line exceptwhen the command line consists of o

Pagina 124

74Modem 34336Table 4-4. Responses To Diagnostic Port Commands.RESPONSE MEANINGERROR Command error (incomplete, wrong syntax, etc.). (If CONNECT or C

Pagina 125

754.0 General Operation and Special Features4.9.4 DTE DISPLAYSWhen Auto-Display is enabled, an update of the LCD is automaticallydisplayed on the DTE

Pagina 126

76Modem 34336• If you want to disconnect from the diagnostic link without establishinga new link, issue the CONNECT command without an address.4.10 Au

Pagina 127 - 7.8 Remote Modem Diagnostics

774.0 General Operation and Special FeaturesChanging the Operating Mode Fallback parameter to 1 has the followingeffects:• The Modem is configured fo

Pagina 128

78Modem 34336Table 4-6. V.22 bis/V.22/V.21/V.23 FALLBACK.MODE DESCRIPTIONV.22 bis 2400 bps asynchronous/ synchronousV.22 1200 and 600 bps asynchrono

Pagina 129

71.0 Specifications V.29 QAM at 9600, 7200, and 4800 bpsV.27 8-phase DPSK at 4800 and 2400 bpsV.26 4-phase DPSK at 2400 and 1200 bpsV.23 FSK at 1200/

Pagina 130

794.0 General Operation and Special FeaturesIf Rate Renegotiation Procedure (RRP) is enabled, the modem willautomatically fall back or fall forward t

Pagina 131

80Modem 34336After you select UP or DOWN, the LCD will automatically switch to the EIAstatus screen so you can see the result of the rate-change reque

Pagina 132 - See notes on page 127

815.0 Hayes Emulation Mode5.0 Hayes Emulation ModeFor easy reference, the following tables appear consecutively at the end of thischapter:• Table 5-1

Pagina 133

82Modem 34336• Command Sequence. For dialing, a command line begins with AT,followed by a D and the phone number. Other commands should beplaced befo

Pagina 134 - See notes on next page

835.0 Hayes Emulation Mode• Dial Command Modifiers. Several modifiers can be used with thebasic D (dial) command to alter dialing operations. The mo

Pagina 135

84Modem 343365.1.3 RESULTCODESResult codes (see Table 5-2) are messages sent by the modem to the DTEmonitor in response to your commands. Result code

Pagina 136 - Appendix C: Summary Setup

855.0 Hayes Emulation ModeFor most commands, there are parameters—numerical values used withthe command specifying the function of the command. For e

Pagina 137

86Modem 34336• H — Telephone Switch Hook. The H command (on-hook) is used toterminate a call. (On-hook corresponds to off-line.) H may also alternate

Pagina 138

875.0 Hayes Emulation Mode• O — Forced On-Line. For asynchronous operation only. When themodem is on-line, you can return to the command state by ent

Pagina 139 - EIA INTERFACE OPTIONS:

88Modem 34336• Z —Recall Stored User Profile. The Z command resets the modem andrecalls a profile of the modem configuration settings previously saved

Pagina 140 - LEASED LINE OPTIONS:

8Modem 343362.0 Quick StartAll information in this manual applies to both the stand-alone and rack-mount versions of the Modem 34336.QUICKSETUPS FOR A

Pagina 141 - DATA PUMP OPTIONS:

895.0 Hayes Emulation Mode• ! — Initiate Flash. The ! command causes the Modem to go on-hook for1/2 second. The command has the same effect as holdin

Pagina 142 - MISCELLANEOUS OPTIONS:

90Modem 34336Ring countWait time before blind dialingWait time for carrier/dial toneIn addition, the &W command does not save stored phone numbers

Pagina 143 - C.3 AT PROFILES Screen

915.0 Hayes Emulation Mode5.3.1 READINGANDSETTINGREGISTERSUse the S command to read the value of a register or to change its value.To read the curren

Pagina 144 - C.4 S-REG Screen

92Modem 34336• S3 — Carriage Return. Register S3 is effective for asynchronous operationonly. Normally, the ASCII carriage-return value, 13, is used.

Pagina 145 - Appendix D: Jumpers

935.0 Hayes Emulation ModeIf the guard time is zero, timing is not a factor. The three escapecharacters can occur with any timing relationship, but t

Pagina 146 - Appendix D: Jumpers

94Modem 343365.4 Selecting Options In Hayes ModeIn Hayes mode, options may be selected by using one of the following:• AT commands (Table 5-1)• The fr

Pagina 147

955.0 Hayes Emulation Mode• If profile 0 is recalled as the active configuration, the LCD screens reflectthe profile 0 configuration.• If profile 0 i

Pagina 148 - INSTRUCCIONES DE SEGURIDAD

96Modem 34336Table 5-1. Hayes Compatible Commands.COMMAND FUNCTION/EXPLANATIONA Quick AnswerNo parameters.A/ Repeat Previous CommandNo parameters.B B

Pagina 149

975.0 Hayes Emulation ModeTable 5-1 (continued). Hayes Compatible Commands.COMMAND FUNCTION/EXPLANATIONI Product Code Or ChecksumI0 Requests product

Pagina 150

98Modem 34336Table 5-1 (continued). Hayes Compatible Commands.COMMAND FUNCTION/EXPLANATIONS= Modify S RegisterParameters are register and value to b

Comentarios a estos manuales