Status Registers
10-20 Modem 3600
Disconnect Buffer Delay S62
The S62 register determines the delay before disconnect, to allow buff-
ers to empty, when disconnect conditions exist.
Maximum Transmit Block Size S63
The S63 register sets the maximum transmit block size.
Auto-Reliable Fallback Character S64
The S64 register stores the selected ASCII value of the auto-reliable
fallback character.
S65-66
Reserved
Bit Value Command Description
7-0 0
1-255
%D
%Dn
Buffer disabled
Disconnect buffer delay value (seconds)
Bit Value Command Description
7-0 63
127
191
255
\A
\A1
\A2
\A3
Maximum block size = 64
Maximum block size = 128
Maximum block size = 192
Maximum block size = 256
Bit Value Command Description
7-0 0
1-127
%A
%An
Disable auto-reliable fallback
character
ASCII value 1-127