Black Box ServSwitch Guía de usuario Pagina 20

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 60
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 19
INSTALLATION
18
3.2 Interconnection Cable Requirements
To connect the Local and Remote Units you will need CATx (any category 5, 5e, 6 or higher)
cable terminated with RJ45 plugs. Please note that shielded cable is advised to maintain
regulatory EMC compliance.
Interconnect cables must be solid-core type. Stranded patch cable will give poor results over
longer distances. The pairing of the cable and pinning of its connectors should normally be in
accordance with EIA-568B.
Pin* Color
(EIA-568B)
Signal
1
2
White/Orange
Orange/White
Blue Video
3
6
White/Green
Green/White
Green Video
4
5
Blue/White
White/Blue
Red Video
7
8
White/Brown
Brown/White
Data
* Looking into the RJ45 socket on a Remote Unit, Pin 1 is on the right and Pin 8 on the left.
EIA-568A wiring can also be used. Contact Technical Support for details.
With some cables, video performance may be improved by using a crossover
patch cable at each end, an alternative RJ45 pin-out or an external skew
correction device (see Appendix C: Advanced Cabling Issues (Skew), page
46).
Vista de pagina 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 59 60

Comentarios a estos manuales

Sin comentarios