Black-box IC171C Manual de usuario

Busca en linea o descarga Manual de usuario para Hardware Black-box IC171C. Black Box IC171C User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 30
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
CUSTOMER
SUPPORT
INFORMATION
Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX
FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746
Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018
Web site: www.blackbox.com • E-mail: [email protected]
MARCH 2000
IC050C
IC171C
RS422/485 Serial Interface Plus
Vista de pagina 0
1 2 3 4 5 6 ... 29 30

Indice de contenidos

Pagina 1 - MARCH 2000

CUSTOMERSUPPORTINFORMATIONOrder toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOXFREE technical support, 24 hours a day,

Pagina 2 - INDUSTRY CANADA

5CHAPTER 2: IntroductionThis interface is ideal for multi-drop or network environments. The RS-485tri-state driver (not dual-state) will allow the ele

Pagina 3 - INSTRUCCIONES DE SEGURIDAD

6RS422/485 SERIAL INTERFACE PLUSNOTEBe sure to set the address selections and jumper options beforeinstallation.The RS422/485 Serial Interface Plus oc

Pagina 4

7CHAPTER 3: Address SelectionFigure 3-1. DIP Switch SW1. Address 3F8 Hex.1 2 3 4ONOFFABCD

Pagina 5 - Contents

8RS422/485 SERIAL INTERFACE PLUSNOTEBe sure to set the address selections and jumper options beforeinstallation.The RS422/485 Serial Interface Plus co

Pagina 6 - 1. Specifications

9CHAPTER 4: Option SelectionFigure 4-2. Header E1 Optional Windows 3.1 Configuration. IRQ 10selected. (Refer to Chapter 6 for more information.)NOTEIR

Pagina 7 - 2. Introduction

10RS422/485 SERIAL INTERFACE PLUSFigure 4-4. Header E2 in Shared Mode.Header E5 is used to control the RS-485 enable/disable functions for thedriver c

Pagina 8 - 2.4 Technical Description

11CHAPTER 4: Option SelectionHeader E3 is used to control the RS-485 enable/disable functions for thereceiver circuit. The RS-485 “Echo” is the result

Pagina 9

12RS422/485 SERIAL INTERFACE PLUSDIP shunt E4 selects the pin out for the DB25 connector P3. With the 5-position shunt in the EIA-530 mode, the RS422/

Pagina 10 - CHAPTER 2: Introduction

13CHAPTER 4: Option SelectionSignal Name Pin # ModeGND Ground 7TDB TX+ Transmit Positive 24 Output RS-422TDA TX- Transmit Negative 25 Output RS-422RD

Pagina 11 - 3. Address Selection

14RS422/485 SERIAL INTERFACE PLUSFigure 4-11. DIP Switch SW2.1 2 3 4ONOFF5LLPPT

Pagina 12 - CHAPTER 3: Address Selection

RS422/485 SERIAL INTERFACE PLUSFEDERAL COMMUNICATIONS COMMISSIONANDINDUSTRY CANADARADIO FREQUENCY INTERFERENCE STATEMENTSThis equipment generates, use

Pagina 13 - 4. Option Selection

15CHAPTER 5: InstallationIMPORTANTYou MUST set up the operating system BEFORE you physically installthe Card.5.1 Software InstallationIf you are inst

Pagina 14 - 31110 12 154275

16RS422/485 SERIAL INTERFACE PLUSNOTEBe sure to set the address selections and jumper options beforeinstallation.1. Turn off PC power. Disconnect the

Pagina 15 - Figure 4-6. Header E5

17CHAPTER 6: Windows 3.1 ConfigurationTo configure the RS422/485 Serial Interface Plus under Windows 3.1, openthe “Control Panel,” which is typically

Pagina 16 - EIA-530 SIO-485

18RS422/485 SERIAL INTERFACE PLUSThe next step is to select the appropriate Baud Rate, Data Bits, Parity, StopBits, and Flow Control.If you wish to se

Pagina 17 - Signal Name Pin # Mode

19CHAPTER 6: Windows 3.1 ConfigurationSelect “OK” for all windows after you have made your selection. The followingmessage should appear:If you wish t

Pagina 18

20RS422/485 SERIAL INTERFACE PLUSComputer does not recognize any COM ports, or the system is “dead” or non-responsive.How to identify the problem: Use

Pagina 19 - Figure 4-11. DIP Switch SW2

21When using Windows 3.1, only two ports at any time are functional.How to identify the problem: Verify that all ports have a separate interrupt, orif

Pagina 20 - 5. Installation

22RS422/485 SERIAL INTERFACE PLUSThe RS422/485 Serial Interface Plus is setup to use the AT interrupts, butthere’s no interrupt response.How to identi

Pagina 21

237.1 Calling Black BoxIf you determine that your RS422/485 Serial Interface Plus is malfunctioning,do not attempt to alter or repair the unit. It co

Pagina 22 - 6. Windows 3.1 Configuration

24RS422/485 SERIAL INTERFACE PLUSSW2C3U474193C2Y1U374193U2C1SLS08-22V10U174LS74U6C5SW1ATPPLLR1BCDRP11AUTORTS422E3RXR275173U8C7R4R3R18R6R5141NSME2D1C9U

Pagina 23 - Settings for COM3:

RS422/485 SERIAL INTERFACE PLUSNORMAS OFICIALES MEXICANAS (NOM)ELECTRICAL SAFETY STATEMENTINSTRUCCIONES DE SEGURIDAD1. Todas las instrucciones de segu

Pagina 24 - System Setting Change

1000 Park Drive • Lawrence, PA 15055-1018 • 724-746-5500 • Fax 724-746-0746© Copyright 2000. Black Box Corporation. All right

Pagina 25 - 7. Troubleshooting

RS422/485 SERIAL INTERFACE PLUS11. El aparato eléctrico deberá ser connectado a una fuente de poder sólodel tipo descrito en el instructivo de operaci

Pagina 26

RS422/485 SERIAL INTERFACE PLUSContentsChapter Page1. Specifications...

Pagina 27

1CHAPTER 1: SpecificationsNumber of Ports — Single RS-485/422Speed — IC050C: 115.2 Kbps; IC171C: 460.8 kbps and higherRS-485 Operation — 2- or 4-wireC

Pagina 28 - CHAPTER 7: Troubleshooting

2RS422/485 SERIAL INTERFACE PLUS2.1 OverviewThe RS422/485 Serial Interface Plus is an easy-to-use RS-485 interface foryour PC. It incorporates unique

Pagina 29

3CHAPTER 2: Introduction2.3 FeaturesListed below are the special features your Serial Interface Plus offers.• Single-channel RS-485/422 adapter for W

Pagina 30

4RS422/485 SERIAL INTERFACE PLUSRS-530 and RS-449RS-530 and RS-449 (EIA-530 and EIA-449) are similar to RS-422 and RS-485 in the fact that they are di

Modelos relacionados RS422/485